Deployment Guide

show hardware stack-unit {0-5} unit {0-0} ipmc-replication
View the internal statistics for each port-pipe (unit) on per port basis.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} port-stats [detail]
View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} register
View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} table-dump {table name}
Environmental Monitoring
Aggregator components use environmental monitoring hardware to detect transmit power readings, receive power readings, and
temperature updates.
To receive periodic power updates, you must enable the following command.
Enable environmental monitoring.
enable optic-info-update interval
Example of the show interfaces transceiver Command
Dell#show int ten 0/49 transceiver
SFP is present
SFP 49 Serial Base ID fields
SFP 49 Id = 0x03
SFP 49 Ext Id = 0x04
SFP 49 Connector = 0x07
SFP 49 Transceiver Code = 0x00 0x00 0x00 0x01 0x20 0x40 0x0c 0x01
SFP 49 Encoding = 0x01
SFP 49 BR Nominal = 0x0c
SFP 49 Length(9um) Km = 0x00
SFP 49 Length(9um) 100m = 0x00
SFP 49 Length(50um) 10m = 0x37
SFP 49 Length(62.5um) 10m = 0x1e
SFP 49 Length(Copper) 10m = 0x00
SFP 49 Vendor Rev =
SFP 49 Laser Wavelength = 850 nm
SFP 49 CheckCodeBase = 0x78
SFP 49 Serial Extended ID fields
SFP 49 Options = 0x00 0x12
SFP 49 BR max = 0
SFP 49 BR min = 0
SFP 49 Vendor SN = P11C0B0
SFP 49 Datecode = 020919
SFP 49 CheckCodeExt = 0xb6
SFP 49 Diagnostic Information
===================================
SFP 49 Rx Power measurement type = Average
===================================
SFP 49 Temp High Alarm threshold = 100.000C
SFP 49 Voltage High Alarm threshold = 5.000V
SFP 49 Bias High Alarm threshold = 100.000mA
SFP 49 TX Power High Alarm threshold = 5.000mW
SFP 49 RX Power High Alarm threshold = 5.000mW
SFP 49 Temp Low Alarm threshold = -50.000C
SFP 49 Voltage Low Alarm threshold = 0.000V
SFP 49 Bias Low Alarm threshold = 0.000mA
SFP 49 TX Power Low Alarm threshold = 0.000mW
SFP 49 RX Power Low Alarm threshold = 0.000mW
342