Deployment Guide

Applying an FCoE Map on Server-facing Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on a server-facing port or port
channel:
The port is congured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by performing FLOGIs on upstream
virtualized FCF ports. The NPG forwards the FLOGIs as FDISC messages to a SAN switch.
1 Congure a server-facing Ethernet port or port channel with an FCoE map.
CONFIGURATION mode
interface {tengigabitEthernet slot/port | port-channel num}
2 Apply the FCoE/FC conguration in an FCoE map on the Ethernet port. Repeat this step to apply an FCoE map to more than one
port.
INTERFACE or INTERFACE PORT_CHANNEL mode
fcoe-map map-name
Dell# interface tengigabitEthernet 0/0
Dell(config-if-te-0/0)# fcoe-map SAN_FABRIC_A
Dell# interface port-channel 3
Dell(config-if-te-0/0)# dcb-map SAN_DCB1
Dell(config-if-po-3)# fcoe-map SAN_FABRIC_A
Dell# interface fortygigabitEthernet 0/48
Dell(config-if-fo-0/0)# fcoe-map SAN_FABRIC_A
3 Enable the port for FCoE transmission using the map settings.
INTERFACE mode
no shutdown
Applying an FCoE Map on Fabric-facing FC Ports
The Aggregator, with the FC ports, are congured by default to operate in N port mode to connect to an F port on an FC switch in a fabric.
You can apply only one FCoE map on an FC port.
When you apply an FCoE map on a fabric-facing FC port, the FC port becomes part of the FCoE fabric, whose settings in the FCoE map
are congured on the port and exported to downstream server CNA ports.
Each Aggregator, with the FC port, is associated with an Ethernet MAC address (FCF MAC address). When you enable a fabric-facing FC
port, the FCoE map applied to the port starts sending FIP multicast advertisements using the parameters in the FCoE map over server-
facing Ethernet ports. A server sees the FC port, with its applied FCoE map, as an FCF port.
1 Congure a fabric-facing FC port.
CONFIGURATION mode
interface fibrechannel slot/port
326
NPIV Proxy Gateway