Deployment Guide

6 Applying an FCoE map on server-facing Ethernet ports
7 Applying an FCoE Map on fabric-facing FC ports
NOTE: All these congurations are available only in PMUX mode and you cannot perform these congurations in Standalone
mode.
Default Congurations in Standalone mode
By default, the following congurations are set in Standalone mode:
1 All the FC port are applied with the default FCoE map.
2 All the 10G server facing ports with the DCBX frames will have the default FCoE map and default DCB map assigned, and without the
DCBX frames, DCB_MAP_PFC_OFF will be applied.
Default DCB map
Dell(conf)#do show qos dcb-map SAN_DCB_MAP
-----------------------
State :Complete
PfcMode:ON
--------------------
PG:0 TSA:ETS BW:30 PFC:OFF
Priorities:0 1 2 5 6 7
PG:1 TSA:ETS BW:30 PFC:OFF
Priorities:4
PG:2 TSA:ETS BW:40 PFC:ON
Priorities:3
Default FCoE map
Dell(conf)#do show fcoe-map
Fabric Name SAN_FABRIC
Fabric Id 1002
Vlan Id 1002
Vlan priority 3
FC-MAP 0efc00
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/9
Te 0/4
DCB_MAP_PFC_OFF
Dell(conf)#do show qos dcb-map DCB_MAP_PFC_OFF
-----------------------
State :In-Progress
PfcMode:OFF
--------------------
Dell(conf)#
322
NPIV Proxy Gateway