Deployment Guide

Link Tracking
By default, all server-facing ports are tracked by the operational status of the uplink LAG. If the uplink LAG goes down, the aggregator
loses its connectivity and is no longer operational; all server-facing ports are brought down after the specied defer-timer interval, which is
10 seconds by default. If you have congured VLAN, you can reduce the defer time by changing the defer-timer value or remove it by using
the no defer-timer command.
NOTE: If installed servers do not have connectivity to a switch, check the Link Status LED of uplink ports on the aggregator. If all
LEDs are on, to ensure the LACP is correctly congured, check the LACP conguration on the ToR switch that is connected to
the aggregator .
Conguring VLANs
By default, in Standalone mode, all aggregator ports belong to all 4094 VLANs and are members of untagged VLAN 1. To congure only the
required VLANs on a port, use the CLI or CMC interface.
You can congure VLANs only on server ports. The uplink LAG will automatically get the VLANs, based on the server ports VLAN
conguration.
When you congure VLANs on server-facing interfaces (ports from 1 to 32), you can assign VLANs to a port or a range of ports by
entering the vlan tagged or vlan untagged commands in Interface Conguration mode; for example:
Dell(conf)# interface range tengigabitethernet 0/2 - 4
Dell(conf-if-range-te-0/2-4)# vlan tagged 5,7,10-12
Dell(conf-if-range-te-0/2-4)# vlan untagged 3
Uplink LAG
The tagged VLAN membership of the uplink LAG is automatically congured based on the VLAN conguration of all server-facing ports
(ports from 1 to 32).
The untagged VLAN used for the uplink LAG is always the default VLAN.
Server-Facing LAGs
The tagged VLAN membership of a server-facing LAG is automatically congured based on the server-facing ports that are members of
the LAG.
The untagged VLAN of a server-facing LAG is congured based on the untagged VLAN to which the lowest numbered server-facing port
in the LAG belongs.
NOTE
: Dell Networking recommends conguring the same VLAN membership on all LAG member ports.
Where to Go From Here
You can customize the Aggregator for use in your data center network as necessary. To perform additional switch conguration, do one of
the following:
For remote out-of-band management, enter the OOB management interface IP address into a Telnet or SSH client and log in to the
switch using the user ID and password to access the CLI.
For local management using the CLI, use the attached console connection.
For remote in-band management from a network management station, enter the IP address of the default VLAN and log in to the
switch to access the CLI.