Deployment Guide

Dell Networking OS uptime is 1 day(s), 4 hour(s), 31 minute(s)
Monitor time: 00:00:00 Refresh Intvl.: 2s
Interface: Te 0/1, Disabled, Link is Down, Linespeed is 1000 Mbit
Traffic statistics: Current Rate Delta
Input bytes: 0 0 Bps 0
Output bytes: 0 0 Bps 0
Input packets: 0 0 pps 0
Output packets: 0 0 pps 0
64B packets: 0 0 pps 0
Over 64B packets: 0 0 pps 0
Over 127B packets: 0 0 pps 0
Over 255B packets: 0 0 pps 0
Over 511B packets: 0 0 pps 0
Over 1023B packets: 0 0 pps 0
Error statistics:
Input underruns: 0 0 pps 0
Input giants: 0 0 pps 0
Input throttles: 0 0 pps 0
Input CRC: 0 0 pps 0
Input IP checksum: 0 0 pps 0
Input overrun: 0 0 pps 0
Output underruns: 0 0 pps 0
Output throttles: 0 0 pps 0
m - Change mode c - Clear screen
l - Page up a - Page down
T - Increase refresh interval t - Decrease refresh interval
q - Quit
Maintenance Using TDR
The time domain reectometer (TDR) is supported on all Dell Networking switch/routers. TDR is an assistance tool to resolve link issues
that helps detect obvious open or short conditions within any of the four copper pairs. TDR sends a signal onto the physical cable and
examines the reection of the signal that returns. By examining the reection, TDR is able to indicate whether there is a cable fault (when
the cable is broken, becomes unterminated, or if a transceiver is unplugged).
TDR is useful for troubleshooting an interface that is not establishing a link, that is, when the link is apping or not coming up. Do not use
TDR on an interface that is passing trac. When a TDR test is run on a physical cable, it is important to shut down the port on the far end
of the cable. Otherwise, it may lead to incorrect test results.
NOTE
: TDR is an intrusive test. Do not run TDR on a link that is up and passing
trac.
To test the condition of cables on 100/1000/10000 BASE-T modules, follow the below steps using the tdr-cable-test command.
1 To test for cable faults on the TenGigabitEthernet cable.
Between two ports, you must not start the test on both ends of the cable.
Enable the interface before starting the test.
The port must be enabled to run the test or the test prints an error message.
EXEC Privilege mode
tdr-cable-test tengigabitethernet <slot>/<port>
2 Displays TDR test results.
EXEC Privilege mode
show tdr tengigabitethernet <slot>/<port>
116
Interfaces