Configuration manual
SFP 49 BR Nominal = 0x0c
SFP 49 Length(9um) Km = 0x00
SFP 49 Length(9um) 100m = 0x00
SFP 49 Length(50um) 10m = 0x37
SFP 49 Length(62.5um) 10m = 0x1e
SFP 49 Length(Copper) 10m = 0x00
SFP 49 Vendor Rev =
SFP 49 Laser Wavelength = 850 nm
SFP 49 CheckCodeBase = 0x78
SFP 49 Serial Extended ID fields
SFP 49 Options = 0x00 0x12
SFP 49 BR max = 0
SFP 49 BR min = 0
SFP 49 Vendor SN = P11C0B0
SFP 49 Datecode = 020919
SFP 49 CheckCodeExt = 0xb6
SFP 49 Diagnostic Information
===================================
SFP 49 Rx Power measurement type = Average
===================================
SFP 49 Temp High Alarm threshold = 100.000C
SFP 49 Voltage High Alarm threshold = 5.000V
SFP 49 Bias High Alarm threshold = 100.000mA
SFP 49 TX Power High Alarm threshold = 5.000mW
SFP 49 RX Power High Alarm threshold = 5.000mW
SFP 49 Temp Low Alarm threshold = -50.000C
SFP 49 Voltage Low Alarm threshold = 0.000V
SFP 49 Bias Low Alarm threshold = 0.000mA
SFP 49 TX Power Low Alarm threshold = 0.000mW
SFP 49 RX Power Low Alarm threshold = 0.000mW
===================================
SFP 49 Temp High Warning threshold = 100.000C
SFP 49 Voltage High Warning threshold = 5.000V
SFP 49 Bias High Warning threshold = 100.000mA
SFP 49 TX Power High Warning threshold = 5.000mW
SFP 49 RX Power High Warning threshold = 5.000mW
SFP 49 Temp Low Warning threshold = -50.000C
SFP 49 Voltage Low Warning threshold = 0.000V
SFP 49 Bias Low Warning threshold = 0.000mA
SFP 49 TX Power Low Warning threshold = 0.000mW
SFP 49 RX Power Low Warning threshold = 0.000mW
===================================
SFP 49 Temperature = 40.844C
SFP 49 Voltage = 3.169V
SFP 49 Tx Bias Current = 0.000mA
SFP 49 Tx Power = 0.000mW
SFP 49 Rx Power = 0.227mW
===================================
SFP 49 Data Ready state Bar = False
SFP 49 Rx LOS state = False
SFP 49 Tx Fault state = False
Recognize an Over-Temperature Condition
An overtemperature condition occurs, for one of two reasons: the card genuinely is too hot or a sensor
has malfunctioned.
Inspect cards adjacent to the one reporting the condition to discover the cause.
• If directly adjacent cards are not normal temperature, suspect a genuine overheating condition.
• If directly adjacent cards are normal temperature, suspect a faulty sensor.