Configuration manual

This view helps identifying the stack unit/port pipe/port that may experience internal drops.
View the input and output statistics for a stack-port interface.
EXEC Privilege mode
show hardware stack-unit {0-5} stack-port {33–56}
View the counters in the field processors of the stack unit.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} counters
View the details of the FP Devices and Hi gig ports on the stack-unit.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} details
Execute a specified bShell command from the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} execute-shell-cmd {command}
View the Multicast IPMC replication table from the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} ipmc-replication
View the internal statistics for each port-pipe (unit) on per port basis.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} port-stats [detail]
View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} register
View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} table-dump {table name}
Environmental Monitoring
Aggregator components use environmental monitoring hardware to detect transmit power readings,
receive power readings, and temperature updates.
To receive periodic power updates, you must enable the following command.
Enable environmental monitoring.
enable optic-info-update interval
Example of the show interfaces transceiver Command
Dell#show int ten 0/49 transceiver
SFP is present
SFP 49 Serial Base ID fields
SFP 49 Id = 0x03
SFP 49 Ext Id = 0x04
SFP 49 Connector = 0x07
SFP 49 Transceiver Code = 0x00 0x00 0x00 0x01 0x20 0x40 0x0c 0x01
SFP 49 Encoding = 0x01
294
Debugging and Diagnostics