Configuration manual

and VLAN ID numbers must be the same.
Fabric and VLAN ID range: 2-4094.
For example: fabric id 10 vlan 10
3
Add a text description of the settings in the
FCoE map.
Maximum: 32 characters.
description text
FCoE MAP
4
Specify the FC-MAP value used to generate a
fabric-provided MAC address, which is
required to send FCoE traffic from a server on
the FCoE VLAN to the FC fabric specified in
Step 2. Enter a unique MAC address prefix as
the FC-MAP value for each fabric.
Range: 0EFC00–0EFCFF.
Default: None.
fc-map
fc-map-value
FCoE MAP
5
Configure the priority used by a server CNA to
select the FCF for a fabric login (FLOGI).
Range: 1-255. Default: 128.
fcf-priority
priority
FCoE MAP
6
Enable the monitoring FIP keep-alive
messages (if it is disabled) to detect if other
FCoE devices are reachable. Default: FIP keep-
alive monitoring is enabled.
keepalive
FCoE MAP
7
Configure the time interval (in seconds) used
to transmit FIP keepalive advertisements.
Range: 8-90 seconds. Default: 8 seconds.
fka-adv-period
seconds
FCoE MAP
Applying an FCoE Map on Server-facing Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on
a server-facing port or port channel:
The port is configured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by
performing FLOGIs on upstream virtualized FCF ports. The NPG forwards the FLOGIs as fabric discovery
(FDISC) messages to a SAN switch.
Step Task Command Command Mode
1
Configure a server-facing Ethernet port or
port channel with an FCoE map.
interface
{tengigabitEthernet
slot/port |
fortygigabitEthernet
CONFIGURATION
FC Flex IO Modules
277