Configuration manual

11 Active T Po128(Te 0/41-42)
T Te 0/1
12 Active T Po128(Te 0/41-42)
T Te 0/1
13 Active T Po128(Te 0/41-42)
T Te 0/1
14 Active T Po128(Te 0/41-42)
T Te 0/1
15 Active T Po128(Te 0/41-42)
T Te 0/1
20 Active U Po128(Te 0/41-42)
U Te 0/1
Dell
You can remove the inactive VLANs that have no member ports using the following command:
Dell#configure
Dell(conf)#no interface vlan <vlan-id>
->vlan-id - Inactive VLAN with no member ports
You can remove the tagged VLANs using the no vlan tagged <VLAN-RANGE> command. You can
remove the untagged VLANs using the no vlan untagged command in the physical port/port-
channel.
Stacking in PMUX Mode
PMUX stacking allows the stacking of two or more IOA units. This allows grouping of multiple units for
high availability. IOA supports a maximum of six stacking units.
NOTE: Prior to configuring the stack-group, ensure the stacking ports are connected and in 40G
native mode.
1. Configure stack groups on all stack units.
Dell#
Dell#configure
Dell(conf)#stack-unit 0 stack-group 0
Dell(conf)#00:37:46: %STKUNIT0-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo
0/33 have been configured as stacking ports. Please save and reset stack-
unit 0 for config to take effect
Dell(conf)#stack-unit 0 stack-group 1
Dell(conf)#00:37:57: %STKUNIT0-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo
0/37 have been configured as stacking ports. Please save and reset stack-
unit 0 for config to take effect
Dell(conf)#end
Dell#00:38:16: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Configured from console
2. Reload the stack units.
Dell#reload
Proceed with reload [confirm yes/no]: yes
3. Show the units stacking status.
Dell#show system brief
Stack MAC : 00:01:e8:e1:e1:c3
Reload-Type : normal-reload [Next boot : normal-reload]
232