Configuration manual

Te 0/53 Te 0/54 Te 0/55 Te 0/56 obsolete after a save and reload.
[confirm yes/no]:yes
Please save and reset unit 0 for the changes to take effect.
Dell(conf)#
2. Save the configuration.
Dell#write memory
!
01:05:48: %STKUNIT0-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config in flash by default
Dell#reload
Proceed with reload [confirm yes/no]: yes
3. Configure the port-channel with 40G member ports.
Dell#configure
Dell(conf)#interface range fortygige 0/33, fortygige 0/37
Dell(conf-if-range-fo-0/33,fo-0/37)#no shut
Dell(conf-if-range-fo-0/33,fo-0/37)#port-channel-protocol lacp
Dell(conf-if-range-fo-0/33,fo-0/37-lacp)#port-channel 20 mode active
Dell(conf)#
Dell(conf)#int fortygige 0/49
Dell(conf-if-fo-0/49)#port-channel-protocol lacp
Dell(conf-if-fo-0/49-lacp)#port-channel 21 mode active
Dell(conf-if-fo-0/49-lacp)#
Dell(conf-if-fo-0/49)#no shut
4. Configure the port mode, VLAN, and so forth on the port-channel.
Dell#configure
Dell(conf)#int port-channel 20
Dell(conf-if-po-20)#portmode hybrid
Dell(conf-if-po-20)#switchport
Dell(conf-if-po-20)#no shut
Dell(conf-if-po-20)#ex
Dell(conf)#int port-channel 21
Dell(conf-if-po-21)#portmode hybrid
Dell(conf-if-po-21)#switchport
Dell(conf-if-po-21)#no shut
Dell(conf-if-po-21)#end
Dell#
5. Show the port channel status.
Dell#sh int port-channel br
Codes: L - LACP Port-channel
O - OpenFlow Controller Port-channel
LAG Mode Status Uptime Ports
L 20 L2 up 00:00:53 Fo 0/33 (Up)
Fo 0/37 (Up)
L 21 L2 up 00:00:02 Fo 0/49 (Up)
Dell#
Dell(conf)#int port-channel 20
Dell(conf-if-po-20)#vlan tagged 1000
Dell(conf-if-po-20)#
Dell(conf-if-po-21)#vlan tagged 1000
% Error: Same VLAN cannot be added to more than one uplink port/LAG.
Dell(conf-if-po-21)#vlan tagged 1001
Dell(conf-if-po-21)#
228
PMUX Mode of the IO Aggregator