Configuration manual
Default Settings
The I/O Aggregator provides zero-touch configuration with the following default configuration settings:
• default user name (root)
• password (calvin)
• VLAN (vlan1) and IP address for in-band management (DHCP)
• IP address for out-of-band (OOB) management (DHCP)
• read-only SNMP community name (public)
• broadcast storm control (enabled in Standalone and VLT modes and disabled in VLT mode)
• IGMP multicast flooding (enabled)
• VLAN configuration (in Standalone mode, all ports belong to all VLANs)
You can change any of these default settings using the CLI. Refer to the appropriate chapter for details.
NOTE: You can also change many of the default settings using the chassis management controller
(CMC) interface. For information about how to access the CMC to configure the aggregator, refer
to the
Dell Chassis Management Controller (CMC) User’s Guide on the Dell Support website at
http://support.dell.com/
Other Auto-Configured Settings
After the Aggregator powers on, it auto-configures and is operational with software features enabled,
including:
• Ports: Ports are administratively up and auto-configured to operate as hybrid ports to transmit tagged
and untagged VLAN traffic.
Ports 1 to 32 are internal server-facing ports, which can operate in 10GbE mode. Ports 33 to 56 are
external ports auto-configured to operate by default as follows:
– The base-module ports operate in standalone 4x10GbE mode. You can configure these ports to
operate in 40GbE stacking mode. When configured for stacking, you cannot use 40GbE base-
module ports for uplinks.
– Ports on the 2-Port 40-GbE QSFP+ module operate only in 4x10GbE mode. You cannot user
them for stacking.
– Ports on the 4-Port 10-GbE SFP+ and 4-Port 10GBASE-T modules operate only in 10GbE mode.
For more information about how ports are numbered, refer to Port Numbering.
• Link aggregation: All uplink ports are configured in a single LAG (LAG 128).
• VLANs: All ports are configured as members of all (4094) VLANs. All VLANs are up and can send or
receive layer 2 traffic. For more information, refer to VLAN Membership.
• Data center bridging capability exchange protocol (DCBx): Server-facing ports auto-configure in
auto-downstream port roles; uplink ports auto-configure in auto-upstream port roles.
• Fibre Channel over Ethernet (FCoE) connectivity and FCoE initiation protocol (FIP) snooping: The
uplink port channel (LAG 128) is enabled to operate in Fibre channel forwarder (FCF) port mode.
• Link layer discovery protocol (LLDP): Enabled on all ports to advertise management TLV and system
name with neighboring devices.