Command Line Reference Guide

Parameters
ip-address Enter the IPv4 address in dotted decimal format.
ipv6-address Enter the IPv6 address in the x:x:x:x::X format.
NOTE: The :: notation specifies successive hexadecimal
fields of zeros.
hostname Enter the name of a host already configured and recognized
by the switch.
Defaults Disabled.
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.2(0.0) Introduced on the M I/O Aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.4.1.0 Added support for IPv6.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Usage
Information
Multiple logging servers of both IPv4 and/or IPv6 can be configured.
Related
Commands
logging trap — enables logging to the Syslog server based on severity.
logging buffered
Enable logging and specify which messages are logged to an internal buffer. By default, all messages are
logged to the internal buffer.
Syntax
logging buffered [level] [size]
To return to the default values, use the default logging buffered command.
To disable logging stored to an internal buffer, use the no logging buffered
command.
430
PMUX Mode of the I/O Aggregator