Administrator Guide
Sensor8 Sensor9
--------------------------------------------------------------------------------
----------------
1 51 51 63 61 61 61 67 61
64 66
Dell#
Example (stack-
unit)
Dell#show environment stack-unit
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
---------------------------------------------------------------------------
* 1 online 66C ok 2
* Management Unit
Dell#
Example
(thermal-sensor)
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
--------------------------------------------------------------------------------
----------------
1 51 51 64 61 61 61 67 61
64 66
Dell#
show inventory
Displays the switch type, components (including media), and Dell Networking OS version including hardware identification
numbers and configured protocols.
Syntax
show inventory [media slot]|[optional-module]}
Parameters
media
slot
(OPTIONAL) Enter the keyword media then the stack ID of the stack member you want to display pluggable media inventory.
optional-module
OPTIONAL) Enter the keyword optional-module to display optional module information.
Defaults none
Command Modes EXEC
Supported Modes All Modes
Command
History
Version Description
8.3.17.0 Supported on the M I/O Aggregator.
Usage
Information
If there are no fiber ports in the unit, just the header under show inventory media displays. If there are fiber ports but no optics inserted, the output displays
"Media not present or accessible".
Example
Dell#show inventory
System Type : PE-FN-410S-IOA
System Mode : 1.0
Software Version : 1-0(0-1859)
Unit Type Serial Number Part Number Rev Piece Part ID Rev Svc Tag Exprs Svc Code
---------------------------------------------------------------------------------------------------------------------
* 0 PowerEdge-FN-410S-IOA TW000000000020 07NVPVX01 X01 TW-07NVPV-00000-000-0020 X01 N/A N/A
* - Management Unit
56 Control and Monitoring