Administrator Guide

Usage
Information
This command is supported on the M I/O, FN410S, and FN410T Aggregators.
This command is used to reset the stack-unit. The master unit can also be power cycled using this
command.
reset stack-unit
Reset any designated stack member except the management unit (master unit).
Syntax
reset stack-unit 05 hard
Parameters
05
Enter the stack member unit identifier of the stack member to reset.
hard
Reset the stack unit if the unit is in a problem state.
Defaults none
Command Modes EXEC Privilege
Supported Modes All Modes
Command
History
Version Description
9.6.(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Usage
Information
This command is supported on the M I/O, FN410S, and FN410T Aggregators
Resetting the management unit is not allowed and an error message displays if you try to do so. Resetting is a soft
reboot, including flushing the forwarding tables.
You can run this command directly on the stack standby unit (Standby Master) to reset the standby. You cannot
reset any other unit from the standby unit
Example
Dell#show system brief
Stack MAC : 00:1e:c9:f1:00:9b
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------------
---
0 Management online I/O-Aggregator I/O-Aggregator 8-3-17-46 56
1 Standby online I/O-Aggregator I/O-Aggregator 8-3-17-46 56
2 Member not present
3 Member not present
4 Member not present
5 Member not present
Dell#
Dell#reset stack-unit 0 >>>Resetting master not allowed
% Error: Reset of master unit is not allowed.
Dell#
Dell#reset stack-unit 1
Dell#01:02:00: %STKUNIT0-M:CP %CHMGR-5-STACKUNIT_RESET: Stack unit 1 being reset
01:02:00: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Te 1/1-32,41-56
01:02:00: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1 down - reset
01:02:00: %STKUNIT1-S:CP %IFMGR-1-DEL_PORT: Removed port: Te 1/1-32,41-56
01:02:05: %I/O-Aggregator:0 %IFAGT-5-STACK_PORT_LINK_DOWN: Changed stack port
state to down: 0/10
01:02:11: %STKUNIT0-M:CP %POLLMGR-2-ALT_STACK_UNIT_STATE: Alternate Stack-unit is
not present
Dell#01:02:12: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1 down - card
removed
Related
Commands
reload reboots the system.
280 Stacking Commands