Administrator Guide

Command Modes
EXEC
EXEC Privilege
Supported Modes All Modes
Command
History
Version Description
9.7(0.0) Introduced on the M I/O Aggregator.
Usage
Information
The following table describes the show fc switch output shown in the following example.
Switch Mode Fibre Channel mode of operation of an Aggregator.
Switch WWN Factory-assigned worldwide node (WWN) name of the Aggregator. The M I/O
Aggregator WWN name is not user-configurable.
Example
Dell(conf)#do show fc switch
Switch Mode : NPG
Switch WWN : 10:00:aa:00:00:00:00:ac
Dell(conf)#
show fcoe-map
Display the Fibre Channel and FCoE configuration parameters in FCoE maps.
M I/O Aggregator with the FC Flex IO module
Syntax
show fcoe-map [brief | map-name]
Parameters
brief Displays an overview of currently configured FCoE maps.
map-name
Displays the FC and FCoE configuration parameters in a specified FCoE map. The
FCoE map is applied on Ethernet (FCoE) and FC ports to transmit FC storage
traffic to a specified fabric.
Command Modes
EXEC
EXEC Privilege
Supported Modes All Modes
Command
History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex
IO module.
Usage
Information
Use the show fcoe-map command to display the FC and FCoE parameters used to configure server-
facing Ethernet (FCoE) and fabric-facing FC ports in all FCoE maps on an M I/O Aggregator with the FC
Flex IO module NPIV proxy gateway.
In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN fabric to which FC
storage traffic is sent, and the FCoE VLAN to be used must be unique.
An FCoE map is used to identify the SAN fabric to which FCoE storage traffic is sent and to virtualize M
I/O Aggregator with the FC Flex IO module FC ports so that they appear to downstream server CNA
ports as FCoE Forwarder (FCF) ports on an FCoE network.
The following table describes the show fcoe-map brief output shown in the example below.
126 FC Flex IO Modules