Administrator Guide
The FC-MAP value is used to generate the fabric-provided MAC address (FP-MAC). The FPMA is used
by servers to transmit FCoE traffic to the fabric. An FC-MAP can be associated with only one FCoE
VLAN and vice versa.
In an FCoE map, the FC-MAP value, fabric ID, and FCoE VLAN parameters must be unique.
To remove a configured FC-MAP value from an FCoE map, enter the no fc-map command.
Related
Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
fcoe-map
Create an FCoE map which contains the parameters used to configure the links between server CNAs and a SAN fabric. Apply
the FCoE map on a server-facing Ethernet port.
M I/O Aggregator with the FC Flex IO module
Syntax
fcoe-map map-name
Parameters
map-name
Maximum: 32 alphanumeric characters.
Defaults On the I/O Aggregator with PMUX modules, the following parameters are applied on all the PMUX
module interfaces:
● Description: SAN_FABRIC
● Fabric-id: 1002
● Fcoe-vlan: 1002
● Fc-map: 0x0efc00
● Fcf-priority: 128
● Fka-adv-period: 8000mSec
● Keepalive: enable
● Vlan priority: 3
Command Modes CONFIGURATION
INTERFACE
Supported Modes Programmable-Mux (PMUX)
Command
History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex
IO module.
Usage
Information
An FCoE map is a template used to map FCoE and FC parameters in a converged fabric. An FCoE map is
used to virtualize upstream FC ports on an M I/O Aggregator with the PMUX module NPIV proxy
gateway so that they appear to downstream server CNA ports as FCoE forwarder (FCF) ports on an
FCoE network. When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map allows
the switch to operate as an FCoE-FC bridge between an FC SAN and an FCoE network by providing
FCoE-enabled servers and switches with the necessary parameters to log in to a SAN fabric.
On an M I/O Aggregator with the PMUX module NPIV proxy gateway, you cannot apply an FCoE map is
applied on fabric-facing FC ports and server-facing 10–Gigabit Ethernet ports.
An FCoE map consists of the following parameters: the dedicated FCoE VLAN used for storage traffic,
the destination SAN fabric (FC-MAP value), FCF priority used by a server, and the FIP keepalive (FKA)
advertisement timeout.
FC Flex IO Modules 123