Addendum

Version
8.3.19.0
Introduced on the S4820T.
Version
8.3.12.0
Introduced on the S4810.
Version 8.4.2.3 Introduced on the S-Series S50.
Usage
Information
You can assign physical port or port-channel interfaces to an uplink-state group.
You can assign an interface to only one uplink-state group. Configure each
interface assigned to an uplink-state group as either an upstream or downstream
interface, but not both.
You can assign individual member ports of a port channel to the group. An uplink-
state group can contain either the member ports of a port channel or the port
channel itself, but not both.
Example
FTOS(conf-uplink-state-group-16)# upstream gigabitethernet
1/10-15
FTOS(conf-uplink-state-group-16)#
Related
Commands
downstream — assigns a port or port-channel to the uplink-state group as a
downstream interface.
uplink-state-group — creates an uplink-state group and enables the tracking of
upstream links.
444
Uplink Failure Detection (UFD)