Users Guide

6 Applying an FCoE map on server-facing Ethernet ports
7 Applying an FCoE Map on fabric-facing FC ports
NOTE: All these configurations are available only in PMUX mode and you cannot perform these configurations in Standalone
mode.
Default Configurations in Standalone mode
By default, the following configurations are set in Standalone mode:
1 All the FC port are applied with the default FCoE map.
2 All the 10G server facing ports with the DCBX frames will have the default FCoE map and default DCB map assigned, and without
the DCBX frames, DCB_MAP_PFC_OFF will be applied.
Default DCB map
Dell(conf)#do show qos dcb-map SAN_DCB_MAP
-----------------------
State :Complete
PfcMode:ON
--------------------
PG:0 TSA:ETS BW:30 PFC:OFF
Priorities:0 1 2 5 6 7
PG:1 TSA:ETS BW:30 PFC:OFF
Priorities:4
PG:2 TSA:ETS BW:40 PFC:ON
Priorities:3
Default FCoE map
Dell(conf)#do show fcoe-map
Fabric Name SAN_FABRIC
Fabric Id 1002
Vlan Id 1002
Vlan priority 3
FC-MAP 0efc00
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/9
Te 0/4
DCB_MAP_PFC_OFF
Dell(conf)#do show qos dcb-map DCB_MAP_PFC_OFF
-----------------------
State :In-Progress
PfcMode:OFF
--------------------
Dell(conf)#
NPIV Proxy Gateway
311