Users Guide
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
In the fabric-id vlan command, the fabric and VLAN ID numbers must be the same.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must be unique.
To remove a fabric-VLAN association from an FCoE map, enter the no fabric-id vlan command.
You must first create a VLAN and then specify the configured VLAN ID in the fabric-id vlan command.
Otherwise, the following error message is displayed.
FTOS(conf-fcoe-f)#fabric-id 10 vlan 10 % Error: Vlan 10 does not exist
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE configuration parameters in FCoE maps.
fcf-priority
In an FCoE map, configure the priority used by a server CNA to select an upstream FCoE forwarder (FCF).
M I/O Aggregator with the FC Flex IO module
Syntax
fcf—priority priority
Parameters
priority Enter the priority assigned to the M I/O Aggregator with the FC Flex IO module NPIV
proxy gateway, which appears to a downstream server CNA as an FCF. The range of
FCF priority values is from 1 to 255.
Defaults 128
Command Modes FCOE MAP
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
The FCF priority you assign to an M I/O Aggregator with the FC Flex IO module is used by server CNAs to select
an upstream FCF to use for a fabric login (FLOGI).
To remove a configured FCF priority from an FCoE map, enter the no fcf-priority command.
FC Flex IO Modules 143