Reference Guide

previous command. Only the last snmp-server host command will be in effect.
For example, if you enter an snmp-server host inform command for a host
and then enter another
snmp-server host inform command for the same
host, the second command replaces the first command.
The snmp-server host command is used with the snmp-server enable
command. Use the snmp-server enable command to specify which SNMP
notifications are sent globally. For a host to receive most notifications, at least one
snmp-server enable command and the snmp-server host command for that
host must be enabled.
NOTE: For v1 / v2c trap configuration, if the community-string is not defined
using the snmp-server community command prior to using this command,
the default form of the
snmp-server community command automatically is
configured with the community-name the same as specified in the snmp-
server host command.
Configuring Informs
To send an inform, use the following steps:
1. Configure a remote engine ID.
2. Configure a remote user.
3. Configure a group for this user with access rights.
4. Enable traps.
5. Configure a host to receive informs.
Related
Commands
snmp-server enable traps — enables SNMP traps.
Syslog Commands
The following commands allow you to configure logging functions on all Dell Networking switches.
clear logging
Clear the messages in the logging buffer.
Syntax
clear logging
Defaults none
Command
Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.2(0.0) Introduced on the M I/O Aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
PMUX Mode of the I/O Aggregator
469