Reference Guide

Command
History
Version 9.3.0.0 Introduced on the FC Flex IO module installed in the M I/O
Aggregator and MXL 10/40GbE Switch
Usage
Information
This command is available at the global level only.
fcoe-map
Create an FCoE map which contains the parameters used to configure the links between server CNAs
and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port.
M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module
Syntax
fcoe-map map-name
Parameters
map-name Maximum: 32 alphanumeric characters.
Defaults None on the MXL 10/40GbE Switch with FC Flex IO modules
On the I/O Aggregator with FC Flex IO modules, the following parameters are
applied on all the FC Flex IO module interfaces:
Description: SAN_FABRIC
Fabric-id: 1002
Fcoe-vlan: 1002
Fc-map: 0x0efc00
Fcf-priority: 128
Fka-adv-period: 8000mSec
Keepalive: enable
Vlan priority: 3
Command
Modes
CONFIGURATION
INTERFACE
Command
History
Version 9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.
Usage
Information
An FCoE map is a template used to map FCoE and FC parameters in a converged
fabric. An FCoE map is used to virtualize upstream FC ports on an M I/O
Aggregator and MXL 10/40GbE Switch with the FC Flex IO module NPIV proxy
gateway so that they appear to downstream server CNA ports as FCoE forwarder
(FCF) ports on an FCoE network. When applied to FC and Ethernet ports on an
NPIV proxy gateway, an FCoE map allows the switch to operate as an FCoE-FC
bridge between an FC SAN and an FCoE network by providing FCoE-enabled
servers and switches with the necessary parameters to log in to a SAN fabric.
FC Flex IO Modules
361