Users Guide

Table 33. show qos dcb-map Field Descriptions
Field Description
State Complete: All mandatory DCB parameters are correctly congured. In progress: The DCB map
conguration is not complete. Some mandatory parameters are not congured.
PFC Mode PFC conguration in the DCB map: On (enabled) or O.
PG Priority group congured in the DCB map.
TSA Transmission scheduling algorithm used in the DCB map: Enhanced Transmission Selection
(ETS).
BW Percentage of bandwidth allocated to the priority group.
PFC PFC setting for the priority group: On (enabled) or O.
Priorities 802.1p priorities congured in the priority group.
show npiv devices brief Command Example
Dell# show npiv devices brief
Total NPIV Devices = 2
------------------------------------------------------------------------------------------------
--------
ENode-Intf ENode-WWPN FCoE-Vlan Fabric-Intf Fabric-Map LoginMethod
Status
------------------------------------------------------------------------------------------------
--------
Te 0/11 20:01:00:10:18:f1:94:20 1003 Fc 0/9 fid_1003 FLOGI
LOGGED_IN
Te 0/12 10:00:00:00:c9:d9:9c:cb 1003 Fc 0/10 fid_1003 FDISC
LOGGED_IN
Table 34. show npiv devices brief Field Descriptions
Field Description
Total NPIV Devices Number of downstream ENodes connected to a fabric over the Aggregator with the NPG.
ENode-Intf Aggregator with the Ethernet interface (slot/port) to which a server CNA is connected.
ENode-WWPN Worldwide port name (WWPN) of a server CNA port.
FCoE-Vlan VLAN ID of the dedicated VLAN used to transmit FCoE trac to and from the fabric.
Fabric-Intf Fabric-facing Fibre Channel port (slot/port) on which FC trac is transmitted to the specied
fabric.
Fabric-Map Name of the FCoE map containing the FCoE/FC conguration parameters for the server
CNA-fabric connection.
Login Method Method used by the server CNA to log in to the fabric; for example: FLOGI - ENode logged in
using a fabric login (FLOGI). FDISC - ENode logged in using a fabric discovery (FDISC).
294 NPIV Proxy Gateway