Users Guide
FCoE Maps
An FCoE map is used to identify the SAN fabric to which FCoE storage trac is sent. Using an FCoE map, an Aggregator with the NPG
operates as an FCoE-FC bridge between an FC SAN and FCoE network by providing FCoE-enabled servers and switches with the
necessary parameters to log in to a SAN fabric.
An FCoE map applies the following parameters on server-facing Ethernet and fabric-facing FC ports on the Aggregator:
• The dedicated FCoE VLAN used to transport FCoE storage trac.
• The FC-MAP value used to generate a fabric-provided MAC address.
• The association between the FCoE VLAN ID and FC fabric ID where the desired storage arrays are installed. Each Fibre Channel fabric
serves as an isolated SAN topology within the same physical network.
• The priority used by a server to select an upstream FCoE forwarder (FCF priority).
• FIP keepalive (FKA) advertisement timeout.
NOTE:
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN must be unique. Use one FCoE map to access one SAN fabric. You
cannot use the same FCoE map to access dierent fabrics.
When you congure an Aggregator with the NPG, FCoE transit with FIP snooping is automatically enabled and congured using the
parameters in the FCoE map applied to server-facing Ethernet and fabric-facing FC interfaces.
After you apply an FCoE map on an FC port, when you enable the port (no shutdown), the NPG starts sending FIP multicast
advertisements on behalf of the FC port to downstream servers in order to advertise the availability of a new FCF port on the FCoE VLAN.
The FIP advertisement also contains a keepalive message to maintain connectivity between a SAN fabric and downstream servers.
Conguring an NPIV Proxy Gateway
Prerequisite: Before you congure an NPIV proxy gateway (NPG) on an Aggregator, ensure that the following features are enabled.
• DCB is enabled by default on the Aggregator.
• Autonegotiated DCBx is enabled for converged trac by default with the Ethernet ports on all Aggregators.
• FCoE transit with FIP snooping is automatically enabled when you congure Fibre Channel on the Aggregator.
To congure an NPG operation on an Aggregator, follow these general conguration steps:
1 Enabling Fibre Channel Capability on the Switch
2 Creating a DCB map
3 Applying a DCB map on server-facing Ethernet ports
4 Creating an FCoE VLAN
5 Creating an FCoE map
6 Applying an FCoE map on server-facing Ethernet ports
7 Applying an FCoE Map on fabric-facing FC ports
NOTE
: All these congurations are available only in PMUX mode and you cannot perform these congurations in Standalone
mode.
Default
Congurations in Standalone mode
By default, the following congurations are set in Standalone mode:
1 All the FC port are applied with the default FCoE map.
2 All the 10G server facing ports with the DCBX frames will have the default FCoE map and default DCB map assigned, and without the
DCBX frames, DCB_MAP_PFC_OFF will be applied.
Default DCB map
Dell(conf)#do show qos dcb-map SAN_DCB_MAP
-----------------------
NPIV Proxy Gateway
285