Users Guide

Command History
Version Description
9.9(0.0) Supported on the FN I/O Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator.
Usage Information
Use the show fcoe-map command to display the FC and FCoE parameters used to congure server-facing
Ethernet (FCoE) and fabric-facing FC ports in all FCoE maps on an M I/O Aggregator Switch.
In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN fabric to which FC storage
trac is sent, and the FCoE VLAN to be used must be unique.
An FCoE map is used to identify the SAN fabric to which FCoE storage trac is sent. It also virtualizes the switch
with the FC Flex IO module FC ports so that they appear to downstream server CNA ports as FCoE Forwarder
(FCF) ports on an FCoE network.
Example
Dell(conf)#do show fcoe-map
Fabric Name SAN_FABRIC
Fabric Type npiv
Fabric Id 1002
Vlan Id 1002
Vlan priority 3
FC-MAP 0efc00
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
=======================================================
Members
Fc 0/41 Fc 0/42 Fc 0/43 Fc 0/44 Fc 0/49 Fc 0/50 Fc 0/51 Fc 0/52
Te 0/4 Te 0/9 Te 0/16
=======================================================
=======================================================
Dell(conf)#
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
160 FC FLEXIO FPORT