Users Guide
Usage Information
FCoE storage trac received from servers on an M I/O Aggregator with the PMUX module NPIV proxy gateway is
de-capsulated into Fibre Channel packets and forwarded over FC links to SAN switches in a specied fabric. You
must congure a separate FCoE VLAN for each fabric to which FCoE trac is forwarded. Any non-FCoE trac
sent on a dedicated FCoE VLAN will be dropped.
You congure the association between a dedicated VLAN, which carries FCoE trac from server CNAs over the
NPIV proxy gateway to a SAN fabric in which destination storage arrays are installed, in an FCoE map by using the
fabric id vlan command.
When you apply an FCoE map to a server-facing Ethernet port, the port is automatically congured as a tagged
member of the FCoE VLAN.
For more information about VLANs and the commands to congure them, refer to the Virtual LAN (VLAN)
Commands section.
Example (Single
Range)
Dell(conf)#interface vlan 10
Dell(conf-if-vl-3)#
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
keepalive
In an FCoE map, enable the monitoring of FIP keepalive messages (if it is disabled).
M I/O Aggregator with the FC Flex IO module
Syntax
keepalive
Parameters None
Defaults FIP keepalive monitoring is enabled on Ethernet and Fibre Channel interfaces.
Command Modes FCOE MAP
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
FIP keepalive (FKA) messaging is used to detect if other FCoE devices are reachable.
To remove FIP keepalive monitoring from an FCoE map, enter the no keepalive command.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
FC Flex IO Modules 143