Administrator Guide

no shutdown
...
Example
(Values)
This Example shows how the Dell Networking OS negotiates the flow control
values between two Dell Networking chassis connected back-to-back using 1G
copper ports.
Configured
LocRxConf LocTxConf RemoteRxConf RemoteTxConf
off off off off
off on
on off
on on
off on off off
off on
on off
on on
on off off off
off on
on off
on on
on on off off
off on
on off
on on
LocNegRx LocNegTx RemNegRx RemNegTx
off off off off
off off off off
off off off off
off off off off
off off off off
off off off off
off on on off
off off off off
off off off off
on off off on
on on on on
on on on on
off off off off
off off off off
on on on on
on on on on
Related
Commands
show running-config — displays the flow configuration parameters (non-default
values only).
show interfaces — displays the negotiated flow control parameters.
392
PMUX Mode of the I/O Aggregator