Users Guide
----------------
HeartBeat Messages Sent: 994
HeartBeat Messages Received: 978
ICL Hello's Sent: 89
ICL Hello's Received: 89
Additional VLT Sample Congurations
To congure VLT, congure a backup link and interconnect trunk, create a VLT domain, congure a backup link and interconnect
trunk, and connect the peer switches in a VLT domain to an attached access device (switch or server).
Review the following examples of VLT congurations.
Conguring Virtual Link Trunking (VLT Peer 1)
Enable VLT and create a VLT domain with a backup-link and interconnect trunk (VLTi).
Dell_VLTpeer1(conf)#vlt domain 999
Dell_VLTpeer1(conf-vlt-domain)#peer-link port-channel 100
Dell_VLTpeer1(conf-vlt-domain)#back-up destination 10.11.206.35
Dell_VLTpeer1(conf-vlt-domain)#exit
Congure the backup link.
Congure the VLT interconnect (VLTi).
Congure the port channel to an attached device.
Verify that the port channels used in the VLT domain are assigned to the same VLAN.
Conguring Virtual Link Trunking (VLT Peer 2)
Enable VLT and create a VLT domain with a backup-link VLT interconnect (VLTi).
Dell_VLTpeer2(conf)#vlt domain 999
Dell_VLTpeer2(conf-vlt-domain)#peer-link port-channel 100
Dell_VLTpeer2(conf-vlt-domain)#back-up destination 10.11.206.23
Dell_VLTpeer2(conf-vlt-domain)#exit
Congure the backup link.
Congure the VLT interconnect (VLTi).
Congure the port channel to an attached device.
Verify that the port channels used in the VLT domain are assigned to the same VLAN.
Verifying a Port-Channel Connection to a VLT Domain (From an Attached Access Switch)
On an access device, verify the port-channel connection to a VLT domain.
Troubleshooting VLT
To help troubleshoot dierent VLT issues that may occur, use the following information.
NOTE: For information on VLT Failure mode timing and its impact, contact your Dell Networking representative.
Table 26. Troubleshooting VLT
Description Behavior at Peer Up Behavior During Run Time Action to Take
Bandwidth monitoring A syslog error message and an
SNMP trap is generated when
the VLTi bandwidth usage goes
A syslog error message and an
SNMP trap is generated when
Depending on the trac that is
received, the trac can be
ooaded inVLTi.
250