Administrator Guide
Range: 0EFC00–0EFCFF.
Default: None.
5
Configure the priority used by a server CNA to
select the FCF for a fabric login (FLOGI).
Range: 1-255. Default: 128.
fcf-priority
priority
FCoE MAP
6
Enable the monitoring FIP keep-alive
messages (if it is disabled) to detect if other
FCoE devices are reachable. Default: FIP keep-
alive monitoring is enabled.
keepalive
FCoE MAP
7
Configure the time interval (in seconds) used
to transmit FIP keepalive advertisements.
Range: 8-90 seconds. Default: 8 seconds.
fka-adv-period
seconds
FCoE MAP
Applying an FCoE Map on Server-facing Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on
a server-facing port or port channel:
• The port is configured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
• The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by
performing FLOGIs on upstream virtualized FCF ports. The NPG forwards the FLOGIs as fabric discovery
(FDISC) messages to a SAN switch.
Step Task Command Command Mode
1
Configure a server-facing Ethernet port or
port channel with an FCoE map.
interface
{tengigabitEthernet
slot/port |
fortygigabitEthernet
slot/port | port-
channel num}
CONFIGURATION
2
Apply the FCoE/FC configuration in an FCoE
map on the Ethernet port. Repeat this step to
apply an FCoE map to more than one port, for
example:
Dell# interface tengigabitEthernet
0/0
Dell(config-if-te-0/0)# fcoe-map
SAN_FABRIC_ADell# interface port-
channel 3
Dell(config-if-po-3)#
fcoe-map SAN_FABRIC_ADell#
interface fortygigabitEthernet
0/48
Dell(config-if-fo-0/0)# fcoe-
map SAN_FABRIC_A
fcoe-map
map-name
INTERFACE or
INTERFACE
PORT_CHANNEL
3
Enable the port for FCoE transmission using
the map settings.
no shutdown
INTERFACE
286
FC Flex IO Modules