Administrator Guide

Range: 0EFC00–0EFCFF.
Default: None.
5
Configure the priority used by a server CNA to
select the FCF for a fabric login (FLOGI).
Range: 1-255. Default: 128.
fcf-priority
priority
FCoE MAP
6
Enable the monitoring FIP keep-alive
messages (if it is disabled) to detect if other
FCoE devices are reachable. Default: FIP keep-
alive monitoring is enabled.
keepalive
FCoE MAP
7
Configure the time interval (in seconds) used
to transmit FIP keepalive advertisements.
Range: 8-90 seconds. Default: 8 seconds.
fka-adv-period
seconds
FCoE MAP
Applying an FCoE Map on Server-facing Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on
a server-facing port or port channel:
The port is configured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by
performing FLOGIs on upstream virtualized FCF ports. The NPG forwards the FLOGIs as fabric discovery
(FDISC) messages to a SAN switch.
Step Task Command Command Mode
1
Configure a server-facing Ethernet port or
port channel with an FCoE map.
interface
{tengigabitEthernet
slot/port |
fortygigabitEthernet
slot/port | port-
channel num}
CONFIGURATION
2
Apply the FCoE/FC configuration in an FCoE
map on the Ethernet port. Repeat this step to
apply an FCoE map to more than one port, for
example:
Dell# interface tengigabitEthernet
0/0
Dell(config-if-te-0/0)# fcoe-map
SAN_FABRIC_ADell# interface port-
channel 3
Dell(config-if-po-3)#
fcoe-map SAN_FABRIC_ADell#
interface fortygigabitEthernet
0/48
Dell(config-if-fo-0/0)# fcoe-
map SAN_FABRIC_A
fcoe-map
map-name
INTERFACE or
INTERFACE
PORT_CHANNEL
3
Enable the port for FCoE transmission using
the map settings.
no shutdown
INTERFACE
286
FC Flex IO Modules