Users Guide

Example (thermal-
sensor)
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
--------------------------------------------------------------------------------
----------------
1 51 51 64 61 61 61 67 61
64 66
Dell#
show inventory
Displays the switch type, components (including media), and Dell Networking OS version including hardware identication numbers
and congured protocols.
Syntax
show inventory [media slot]|[optional-module]}
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member you want to display pluggable media inventory.
optional-module
OPTIONAL) Enter the keyword optional-module to display optional module information.
Defaults none
Command Modes EXEC
Supported Modes All Modes
Command History
Version Description
8.3.17.0 Supported on the M I/O Aggregator.
Usage Information If there are no ber ports in the unit, just the header under show inventory media displays. If there are ber ports but no optics inserted, the output displays
"Media not present or accessible".
Example
Dell#show inventory
System Type : PE-FN-410S-IOA
System Mode : 1.0
Software Version : 1-0(0-1859)
Unit Type Serial Number Part Number Rev Piece Part ID Rev Svc Tag Exprs Svc Code
---------------------------------------------------------------------------------------------------------------------
* 0 PowerEdge-FN-410S-IOA TW000000000020 07NVPVX01 X01 TW-07NVPV-00000-000-0020 X01 N/A N/A
* - Management Unit
Software Protocol Configured
--------------------------------------------------------------
DCBX
FIP Snooping
IGMP
iSCSI
LLDP
SNMP
Dell#