Users Guide
Version Description
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
show environment
Displays the system component status (for example, temperature or voltage).
Syntax
show environment [all | stack-unit unit-id]
Parameters
all Enter the keyword all to view all components.
stack-unit unit-id Enter the keywords stack-unit then the unit-id to display information on a specic
stack member. The range is from 0 to 5.
thermal sensor Enter the keywords thermal-sensor to view all components.
Command Modes
• EXEC
• EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Example (all)
Dell#show environment all
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
---------------------------------------------------------------------------
* 1 online 66C ok 2
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
--------------------------------------------------------------------------------
----------------
1 51 51 63 61 61 61 67 61
64 66
Dell#
Example (stack-unit)
Dell#show environment stack-unit
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
---------------------------------------------------------------------------
* 1 online 66C ok 2
* Management Unit
Dell#
62