Users Guide
monitor interface
Monitor counters on a single interface or all interfaces on a stack unit. The screen is refreshed every ve seconds and the CLI
prompt disappears.
Syntax
monitor interface [interface]
To disable monitoring and return to the CLI prompt, press the q key.
Parameters
interface (OPTIONAL) Enter the following keywords and slot/port or number information:
• For the management port, enter the keyword managementethernet
followed by the slot (0 or 1) and the port (0).
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet followed by the slot/port information.
•
For a Port Channel interface, enter the keyword port-channel followed by a
number. The range is from 1 to 4094.
Command Modes
• EXEC
• EXEC Privilege
Supported Modes All Modes
Command History
Version Description
8.3.17.0 Supported on M I/O Aggregator.
Usage Information The delta column displays changes since the last screen refresh.
The following are the monitor command menu options.
Key Description
systest-3 Displays the host name assigned to the system.
monitor time Displays the amount of time since the monitor interface command was
entered.
time Displays the amount of time the chassis is up (since last reboot).
m Change the view from a single interface to all interfaces on the stack unit or visa-
versa.
c Refresh the view.
b Change the counters displayed from Packets on the interface to Bytes.
r Change the [delta] column from change in the number of packets/bytes in the last
interval to rate per second.
l Change the view to the next interface on the stack unit, or if in the stack unit
mode, the next stack unit in the chassis.
a Change the view to the previous interface on the stack unit, or if in line stack unit
mode, the previous stack unit in the chassis.
T Increase the screen refresh rate.
t Decrease the screen refresh rate.
204
Interfaces