Users Guide
Dell#show fc ns fabric
Total number of devices = 3
Switch Name 10:00:5c:f9:dd:ef:0a:80
Domain Id 2
Switch Port 9
Port Id 02:09:00
Port Name 32:11:0e:fc:00:00:00:88
Node Name 22:11:0e:fc:00:00:00:88
Class of Service 8
IP Address
Symbolic Port Name (NULL)
Symbolic Node Name (NULL)
Port Type Node port
Registered with NameServer No
Registered for SCN No
Switch Name 10:00:5c:f9:dd:ef:0a:80
Domain Id 2
Switch Port 11
Port Id 02:0b:00
Port Name 31:11:0e:fc:00:00:00:77
Node Name 21:11:0e:fc:00:00:00:77
Class of Service 8
IP Address
Symbolic Port Name (NULL)
Symbolic Node Name (NULL)
Port Type Node port
Registered with NameServer No
Registered for SCN No
Switch Name 10:00:5c:f9:dd:ef:0a:00
Domain Id 1
Switch Port 53
Port Id 01:35:00
Port Name 10:00:8c:7c:ff:17:f8:01
Node Name 20:00:8c:7c:ff:17:f8:01
Class of Service 8
IP Address
Symbolic Port Name Brocade-1860 | 3.0.3.0 | DV-SP-SERVER2 | |
Symbolic Node Name (NULL)
Port Type Node port
Registered with NameServer Yes
Registered for SCN Yes
Dell#
Dell#show fc ns fabric brief
Total number of devices = 2
Intf# Domain FC-ID Enode-WWPN Enode-WWNN
9 2 02:09:00 32:11:0e:fc:00:00:00:88 22:11:0e:fc:
00:00:00:88
11 2 02:0b:00 31:11:0e:fc:00:00:00:77 21:11:0e:fc:
00:00:00:77
Dell#
show fc switch
Display the switch conguration for Fibre Channel capability.
Syntax
show fc switch
Parameters None
Command Modes
• EXEC
160
FC FLEXIO FPORT