Users Guide
On the switch NPIV proxy gateway, an FCoE map is applied on fabric-facing FC ports and server-facing
Ethernet ports. Use the fabric command to apply an FCoE map on an FC port. Use the fcoe-map
command to apply an FCoE map on an Ethernet port.
After you apply an FCoE map on an FC interface, when the port is enabled (no shutdown), the NPIV
proxy gateway starts sending FIP multicast advertisements on behalf of the FC port to downstream servers
to advertise the availability of a new FCF port on the FCoE VLAN.
To remove an FCoE map from an FC interface, enter the no fabric map-name command in Interface
conguration mode.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
fc alias
Create a zone alias name.
Syntax
fc alias ZoneAliasNamemember name
To delete a zone alias name, use the no fc zone ZoneAliasName command.
Parameters
ZoneAliasNameme
mber name
Enter the zone alias name.
Enter the WWPN, port ID, or domain/port.
Command Modes CONFIGURATION
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Supported on the FN I/O Aggregator.
9.7(0.0) Introduced on the M I/O Aggregator.
Example
Syntax:
Dell(conf)#fc alias test12
Dell(conf-fc-alias-test12)#?
end Exit from configuration mode
exit Exit from Alias config mode
member Add Alias member
no Negate a command or set its defaults
show Show alias profile configuration
Dell(conf-fc-alias-test12)#member ?
WORD WWN(00:00:00:00:00:00:00:00), or portID(123000)
Related Commands
show fc alias — displays the congured alias.
FC FLEXIO FPORT