Users Guide
Parameters
fc-map-value Enter the unique MAC address prex used by a SAN fabric.
The range of FC-MAP values is from 0EFC00 to 0EFCFF.
Defaults None
Command Modes FCoE MAP
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN 2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex
IO module.
Usage Information
The FC-MAP value you enter must match the FC-MAP value used by an FC switch or FCoE forwarder
(FCF) in the fabric. An FCF switch accepts only FCoE trac that uses the correct FC-MAP value.
The FC-MAP value is used to generate the fabric-provided MAC address (FP-MAC). The FPMA is used by
servers to transmit FCoE trac to the fabric. An FC-MAP can be associated with only one FCoE VLAN and
vice versa.
In an FCoE map, the FC-MAP value, fabric ID, and FCoE VLAN parameters must be unique.
To remove a congured FC-MAP value from an FCoE map, enter the no fc-map command.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
fcoe-map
Create an FCoE map which contains the parameters used to congure the links between server CNAs and a SAN fabric. Apply the
FCoE map on a server-facing Ethernet port.
Syntax
fcoe-map map-name
Parameters
map-name Maximum: 32 alphanumeric characters.
Defaults On the FN2210S Aggregator with PMUX modules, the following parameters are applied on all the PMUX
module interfaces:
• Description: SAN_FABRIC
• Fabric-id: 1002
• Fcoe-vlan: 1002
• Fc-map: 0x0efc00
• Fcf-priority: 128
110