Administrator Guide
Add a text description. The
maximum is 32 characters.
description text
FCoE MAP
Specify the FC-MAP value used
to generate a fabric-provided
MAC address. You must enter a
unique MAC address prefix as the
FC-MAP value for each fabric.
The range is from 0EFC00 to
0EFCFF. The default is None.
fc-map
fc-map-value
FCoE MAP
Configure the priority used by a
server CNA to select the FCF for
a fabric login (FLOGI). The range
is from 0 to 128. The default is
128.
fcf-priority
priority
FCoE MAP
Enable the monitoring FIP
keepalive messages (if it is
disabled) to detect if other FCoE
devices are reachable. The
default is enabled.
keepalive
FCoE MAP
Configure the time (in seconds)
used to transmit FIP keepalive
advertisements. The range is 8 to
90 seconds. The default is 8
seconds.
fka-adv-period
seconds
FCoE MAP
Applying a DCB Map on Server-Facing Ethernet Ports
You can apply a DCB map only on a physical Ethernet interface and can apply only one DCB map per
interface.
Task
Command Command Mode
Enter Interface Configuration
mode on a server-facing port to
apply a DCB map.
interface
{tengigabitEthernet slot/
port |
fortygigabitEthernet
slot/port}
CONFIGURATION
Apply the DCB map on an
Ethernet port. Repeat this step to
apply a DCB map to more than
one port.
dcb-map
name
INTERFACE
Applying an FCoE Map on Fabric-Facing FC Ports
The IOA and MXL switch with the FC Flex IO module FC ports are configured by default to operate in N
port mode. When you apply an FCoE map on a fabric-facing FC port, the FC port becomes part of the
FCoE fabric.
Each IOA and MXL switch with the FC Flex IO module FC port is associated with an Ethernet MAC address
(FCF MAC address). When you enable a fabric-facing FC port, the FCoE map applied to the port starts
240
PMUX Mode of the IO Aggregator