Users Guide
SFP 49 TX Power High Alarm threshold = 5.000mW
SFP 49 RX Power High Alarm threshold = 5.000mW
SFP 49 Temp Low Alarm threshold = -50.000C
SFP 49 Voltage Low Alarm threshold = 0.000V
SFP 49 Bias Low Alarm threshold = 0.000mA
SFP 49 TX Power Low Alarm threshold = 0.000mW
SFP 49 RX Power Low Alarm threshold = 0.000mW
===================================
SFP 49 Temp High Warning threshold = 100.000C
SFP 49 Voltage High Warning threshold = 5.000V
SFP 49 Bias High Warning threshold = 100.000mA
SFP 49 TX Power High Warning threshold = 5.000mW
SFP 49 RX Power High Warning threshold = 5.000mW
SFP 49 Temp Low Warning threshold = -50.000C
SFP 49 Voltage Low Warning threshold = 0.000V
SFP 49 Bias Low Warning threshold = 0.000mA
SFP 49 TX Power Low Warning threshold = 0.000mW
SFP 49 RX Power Low Warning threshold = 0.000mW
===================================
SFP 49 Temperature = 40.844C
SFP 49 Voltage = 3.169V
SFP 49 Tx Bias Current = 0.000mA
SFP 49 Tx Power = 0.000mW
SFP 49 Rx Power = 0.227mW
===================================
SFP 49 Data Ready state Bar = False
SFP 49 Rx LOS state = False
SFP 49 Tx Fault state = False
Recognize an Over-Temperature Condition
An overtemperature condition occurs, for one of two reasons: the card genuinely is too hot or a sensor
has malfunctioned.
Inspect cards adjacent to the one reporting the condition to discover the cause.
• If directly adjacent cards are not normal temperature, suspect a genuine overheating condition.
• If directly adjacent cards are normal temperature, suspect a faulty sensor.
When the system detects a genuine over-temperature condition, it powers off the card. To recognize this
condition, look for the following system messages:
CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (temperature reaches
or exceeds threshold of
[value]C)
CHMGR-2-TEMP_SHUTDOWN_WARN: WARNING! temperature is [value]C; approaching
shutdown threshold of [value]C
To view the programmed alarm thresholds levels, including the shutdown value, use the show alarms
threshold command.
NOTE: When the ingress air temperature exceeds 61°C, the Status LED turns Amber and a major
alarm is triggered.
Example of the show alarms threshold Command
Dell#show alarms threshold
-- Temperature Limits (deg C) --
-----------------------------------------------------------------------------
Ingress-Air Off Ingress-Air Major Off Major Shutdown
332
Debugging and Diagnostics