Users Guide

Step Task Command Command Mode
7
Configure the time interval (in seconds) used
to transmit FIP keepalive advertisements.
Range: 8–90 seconds. Default: 8 seconds.
fka-adv-period
seconds
FCoE MAP
Applying an FCoE Map on Server-facing Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on
a server-facing port or port channel:
The port is configured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by
performing FLOGIs on upstream virtualized FCF ports. The NPG forwards the FLOGIs as FDISC messages
to a SAN switch.
Step Task Command Command Mode
1
Configure a server-facing Ethernet port or
port channel with an FCoE map.
interface
{tengigabitEthernet
slot/port | port-
channel num}
CONFIGURATION
2
Apply the FCoE/FC configuration in an FCoE
map on the Ethernet port. Repeat this step to
apply an FCoE map to more than one port, for
example:
Dell# interface tengigabitEthernet
0/0
Dell(config-if-te-0/0)# fcoe-map
SAN_FABRIC_A
Dell# interface port-channel 3
Dell(config-if-te-0/0)# dcb-map
SAN_DCB1
Dell(config-if-po-3)# fcoe-map
SAN_FABRIC_A
Dell# interface
fortygigabitEthernet 0/48
Dell(config-if-fo-0/0)# fcoe-map
SAN_FABRIC_A
fcoe-map map-name
INTERFACE or
INTERFACE
PORT_CHANNEL
3
Enable the port for FCoE transmission using
the map settings.
no shutdown
INTERFACE
Applying an FCoE Map on Fabric-facing FC Ports
The Aggregator, with the FC ports, are configured by default to operate in N port mode to connect to an
F port on an FC switch in a fabric. You can apply only one FCoE map on an FC port.
NPIV Proxy Gateway
313