Users Guide
Dell(conf-mon-sess-300)# source tengig 0/17 destination tengig 0/33 direction tx
Dell(conf-mon-sess-300)# do show monitor session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 TenGig 0/13 TenGig 0/33 rx interface Port-based
10 TenGig 0/14 TenGig 0/34 rx interface Port-based
20 TenGig 0/15 TenGig 0/35 rx interface Port-based
30 TenGig 0/16 TenGig 0/37 rx interface Port-based
300 TenGig 0/17 TenGig 0/33 tx interface Port-based
Dell(conf-mon-sess-300)#
The following example shows ports 0/25 and 0/26 that belong to port pipe 1 with a maximum of four
destination ports.
Dell(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 TenGig 0/13 TenGig 0/33 rx interface Port-based
10 TenGig 0/14 TenGig 0/34 rx interface Port-based
20 TenGig 0/15 TenGig 0/35 rx interface Port-based
30 TenGig 0/16 TenGig 0/37 rx interface Port-based
100 TenGig 0/25 TenGig 0/38 tx interface Port-based
110 TenGig 0/26 TenGig 0/39 tx interface Port-based
300 TenGig 0/17 TenGig 0/33 tx interface Port-based
Dell(conf-mon-sess-300)#
In the example below, 0/25 and 0/26 belong to Port-pipe 1. This port-pipe has the same restriction of
only four destination ports, new or used.
Dell(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 TenGig 0/13 TenGig 0/1 rx interface Port-based
10 TenGig 0/14 TenGig 0/2 rx interface Port-based
20 TenGig 0/15 TenGig 0/3 rx interface Port-based
30 TenGig 0/16 TenGig 0/37 rx interface Port-based
100 TenGig 0/25 TenGig 0/38 tx interface Port-based
110 TenGig 0/26 TenGig 0/39 tx interface Port-based
300 TenGig 0/17 TenGig 0/1 tx interface Port-based
Dell(conf-mon-sess-300)#
A source port may only be monitored by one destination port (% Error: Exceeding max MG ports
for this MD port pipe.), but a destination port may monitor more than one source port.
Dell Networking OS Behavior: All monitored frames are tagged if the configured monitoring direction is
transmit (TX), regardless of whether the monitored port (MD) is a Layer 2 or Layer 3 port.
• If the MD port is a Layer 2 port, the frames are tagged with the VLAN ID of the VLAN to which the MD
belongs.
• If the MD port is a Layer 3 port, the frames are tagged with VLAN ID 4095.
• If the MD port is in a Layer 3 VLAN, the frames are tagged with the respective Layer 3 VLAN ID.
For example, in the configuration source tengig 1/1 destination tengig 1/41 direction tx, if the source port
1/1 is an untagged memberof any VLAN, all monitored frames that the destination port 1/41 receives are
tagged with the VLAN ID of the source port.
186
Port Monitoring