Owner`s manual

Port Monitoring | 193
Command Modes
CONFIGURATION
Command
History
Example
Figure 17-1. monitor session Command Example
Usage
Information
The monitor command is saved in the running configuration at the Monitor Session mode level and can
be restored after a chassis reload.
Related
Commands
show config
Displays the current monitor session configuration.
Syntax
show config
Defaults
none
Command Modes
MONITOR SESSION (conf-mon-sess-session-ID)
Command
History
Example
Figure 17-2. show config Command Example
show monitor session
Displays the monitor information of a particular session or all sessions.
Syntax
show monitor session {session-ID}
To display monitoring information for all sessions, use the show monitor session command.
Parameters
Defaults
none
Version 8.3.17.0 Supported on M I/O Aggregator
FTOS(conf)# monitor session 60
FTOS(conf-mon-sess-60)
description Displays the monitor session
show running-config monitor session Displays the running configuration of a monitor session
Version 8.3.17.0 Supported on M I/O Aggregator
FTOS(conf-mon-sess-5)#show config
!
monitor session 5
source TenGigabitEthernet 0/4 destination TenGigabitEthernet 0/43 direction rx
FTOS(conf-mon-sess-5)#
session-ID
(OPTIONAL) Enter a session identification number.
Range: 0 to 65535