Deployment Guide
1/37 0/37 40 up up
Dell#
Example (Status)
Dell# show system stack-ports status
Topology: Daisy chain
Interface Link Speed Admin Link Trunk
(Gb/s) Status Status Group
0/33 40 up down
0/37 40 up up
1/33 40 up down
1/37 40 up up
Example (Topology)
Dell# show system stack-ports topology
Topology: Daisy chain
Interface Connection Trunk
Group
0/33
0/37 1/37
1/33
1/37 0/37
Dell #
Related Commands
power-cycle stack-unit—resets the designated stack member.
show diag— displays the data plane or management plane input and output statistics of the designated
component of the designated stack member.
show system—displays the current status of all stack members or a specic member.
show system stack-unit fanout
Displays the current 40GbE ports congured in fanout mode.
Syntax
show system stack-unit <unit-number> fanout[configured]
Parameters
unit-number <0–5> Enter the number of the member stack unit. The range is from 0 to 5.
Defaults none
Command Modes
• EXEC Privilege
Supported Modes All Modes
Command History
Version Description
8.3.17.0 Supported on the M I/O Aggregator.
Example
Dell#show system stack-unit 0 fanout ?
configured Configured fan out ports
Dell#show system stack-unit 0 fanout configured ?
| Pipe through a command
<cr>
Dell#show system stack-unit 0 fanout configured
Configured fan out ports in stack-unit 0
Configured Next Boot
33 33
368 Stacking Commands