Deployment Guide
Defaults Not congured.
Command Modes CONFIGURATION
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module congured as an NPIV proxy gateway.
Usage Information
FCoE storage trac received from servers on an M I/O Aggregator with the PMUX module NPIV proxy gateway is
de-capsulated into Fibre Channel packets and forwarded over FC links to SAN switches in a specied fabric. You
must congure a separate FCoE VLAN for each fabric to which FCoE trac is forwarded. Any non-FCoE trac
sent on a dedicated FCoE VLAN will be dropped.
You congure the association between a dedicated VLAN, which carries FCoE trac from server CNAs over the
NPIV proxy gateway to a SAN fabric in which destination storage arrays are installed, in an FCoE map by using the
fabric id vlan command.
When you apply an FCoE map to a server-facing Ethernet port, the port is automatically congured as a tagged
member of the FCoE VLAN.
For more information about VLANs and the commands to congure them, refer to the Virtual LAN (VLAN)
Commands section.
Example (Single
Range)
Dell(conf)#interface vlan 10
Dell(conf-if-vl-3)#
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
keepalive
In an FCoE map, enable the monitoring of FIP keepalive messages (if it is disabled).
M I/O Aggregator with the FC Flex IO module
Syntax
keepalive
Parameters None
Defaults FIP keepalive monitoring is enabled on Ethernet and Fibre Channel interfaces.
Command Modes FCOE MAP
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
FC Flex IO Modules 149