Deployment Guide
To remove a congured FC-MAP value from an FCoE map, enter the no fc-map command.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
fcoe-map
Create an FCoE map which contains the parameters used to congure the links between server CNAs and a SAN fabric. Apply the FCoE
map on a server-facing Ethernet port.
Syntax
fcoe-map map-name
Parameters
map-name Maximum: 32 alphanumeric characters.
Defaults On the FN2210S Aggregator with PMUX modules, the following parameters are applied on all the PMUX module
interfaces:
• Description: SAN_FABRIC
• Fabric-id: 1002
• Fcoe-vlan: 1002
• Fc-map: 0x0efc00
• Fcf-priority: 128
• Fka-adv-period: 8000mSec
• Keepalive: enable
• Vlan priority: 3
Command Modes CONFIGURATION
INTERFACE
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator.
Usage Information
An FCoE map is a template used to map FCoE and FC parameters in a converged fabric. An FCoE map is used to
virtualize upstream FC ports on an FN2210S Aggregator with the PMUX module NPIV proxy gateway so that they
appear to downstream server CNA ports as FCoE forwarder (FCF) ports on an FCoE network. When applied to FC
and Ethernet ports on an NPIV proxy gateway, an FCoE map allows the switch to operate as an FCoE-FC bridge
between an FC SAN and an FCoE network by providing FCoE-enabled servers and switches with the necessary
parameters to log in to a SAN fabric.
On an FN2210S Aggregator a with the PMUX module NPIV proxy gateway, you cannot apply an FCoE map applied
on fabric-facing FC ports and server-facing 10–Gigabit Ethernet ports.
Data Center Bridging (DCB) 113