Failure Scenarios
The following sections describe some of the common fault conditions that can happen in a switch stack and how they are resolved.
Stack Member Fails
• Problem: A unit that is not the stack master fails in an operational stack.
• Resolution: If a stack member fails in a daisy chain topology, a split stack occurs. If a member unit fails in a ring topology, trac is re-
routed over existing stack links.
The following syslog messages are generated when a member unit fails:
Dell#May 31 01:46:17: %STKUNIT3-M:CP %IPC-2-STATUS: target stack unit 4 not responding
May 31 01:46:17: %STKUNIT3-M:CP %CHMGR-2-STACKUNIT_DOWN: Major alarm: Stack unit 4 down - IPC
timeout
Dell#May 31 01:46:17: %STKUNIT3-M:CP %IFMGR-1-DEL_PORT: Removed port: Te 4/1-32,41-48, Fo 4/
49,53
Dell#May 31 01:46:18: %STKUNIT5-S:CP %IFMGR-1-DEL_PORT: Removed port: Te 4/1-32,41-48, Fo 4/
49,53
Unplugged Stacking Cable
• Problem: A stacking cable is unplugged from a member switch. The stack loses half of its bandwidth from the disconnected switch.
• Resolution: Intra-stack trac is re-routed on a another link using the redundant stacking port on the switch. A recalculation of control
plane and data plane connections is performed.
Master Switch Fails
• Problem: The master switch fails due to a hardware fault, software crash, or power loss.
• Resolution: A failover procedure begins:
1 Keep-alive messages from the Aggregator master switch time out after 60 seconds and the switch is removed from the stack.
2 The standby switch takes the master role. Data trac on the new master switch is uninterrupted. Protocol trac is managed by the
control plane.
3 A member switch is elected as the new standby. Data trac on the new standby is uninterrupted. The control plane prepares for
operation in Warm Standby mode.
Stack-Link Flapping Error
Problem/Resolution: Stacked Aggregators monitor their own stack ports and disable any stack port that aps ve times within 10
seconds. If the stacking ports that ap are on the master or standby, KERN-2-INT error messages note the units
To re-enable a downed stacking port, power cycle the stacked switch on which the port is installed.