Administrator Guide
Reason Description
PFC is down (show
interfaces pfc
output)
One of the following PFC-specic errors has occurred:
• No MBC support.
• Congured PFC priorities exceed maximum PFC capability limit.
• New dot1p-to-queue mapping violates the allowed system limit for PFC Enable status per priority
ETS is down (show
interfaces ets
output)
One of the following ETS-specic errors occurred in ETS validation:
• Unsupported PGID
• A priority group exceeds the maximum number of supported priorities.
• COSQ is mapped to more than one priority group.
• COSQ is mapped to more than one priority group. - Invalid or unsupported transmission selection
algorithm (TSA).
• Bandwidth is congured for an uncongured priority group.
• Total ETS bandwidth mapped in priority groups is not equal to 100%.
• Priorities mapped to a queue use dierent TSAs.
• Total bandwidth assigned to priorities in one or more priority groups is not equal to 100%.
Or one of the following ETS failure errors occurred:
• Incompatible priority group ID (PGID).
• Incompatible bandwidth (BW) allocation.
• Incompatible TSA.
• Incompatible TC BW.
• Incompatible TC TSA.
Data Center Bridging (DCB)