Administrator Guide

Reason Description
PFC is down (show
interfaces pfc
output)
One of the following PFC-specic errors has occurred:
No MBC support.
Congured PFC priorities exceed maximum PFC capability limit.
New dot1p-to-queue mapping violates the allowed system limit for PFC Enable status per priority
ETS is down (show
interfaces ets
output)
One of the following ETS-specic errors occurred in ETS validation:
Unsupported PGID
A priority group exceeds the maximum number of supported priorities.
COSQ is mapped to more than one priority group.
COSQ is mapped to more than one priority group. - Invalid or unsupported transmission selection
algorithm (TSA).
Bandwidth is congured for an uncongured priority group.
Total ETS bandwidth mapped in priority groups is not equal to 100%.
Priorities mapped to a queue use dierent TSAs.
Total bandwidth assigned to priorities in one or more priority groups is not equal to 100%.
Or one of the following ETS failure errors occurred:
Incompatible priority group ID (PGID).
Incompatible bandwidth (BW) allocation.
Incompatible TSA.
Incompatible TC BW.
Incompatible TC TSA.
Data Center Bridging (DCB)
55