Administrator Guide

fid_1004 1004 1004 0efc04 128 ACTIVE DOWN
Dell# show fcoe-map fid_1003
Fabric Name fid_1003
Fabric Id 1003
Vlan Id 1003
Vlan priority 3
FC-MAP 0efc03
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/9
Te 0/11 Te 0/12
Table 26. show fcoe-map Field Descriptions
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated VLAN used to transport FCoE storage trac between servers and a fabric
over the NPG. The congured VLAN ID must be the same as the fabric ID.
VLAN priority FCoE trac uses VLAN priority 3. This setting is not user-congurable.
FC-MAP FCoE MAC-address prex value - The unique 24-bit MAC address prex that identies a
fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive advertisements.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Cong-State Indicates whether the congured FCoE and FC parameters in the FCoE map are valid:
Active (all mandatory FCoE and FC parameters are correctly congured) or Incomplete
(either the FC-MAP value, fabric ID, or VLAN ID are not correctly congured).
Oper-State Operational status of the link to the fabric: up (link is up and transmitting FC trac), down
(link is down and not transmitting FC trac), link-wait (link is up and waiting for FLOGI to
complete on peer FC port), or removed (port has been shut down).
Members Aggregator with the FC ports, which are members of the dedicated FCoE VLAN that
carries storage trac to the specied fabric.
show qos dcb-map Command Examples
Dell# show qos dcb-map dcbmap2
State :Complete
PfcMode:ON
--------------------
PG:0 TSA:ETS BW:50 PFC:OFF
Priorities:0 1 2 4 5 6 7
PG:1 TSA:ETS BW:50 PFC:ON
Priorities:3
NPIV Proxy Gateway
259