Administrator Guide
Step Task Command Command Mode
3
Enable the port for FCoE transmission using the map
settings.
no shutdown
INTERFACE
Applying an FCoE Map on Fabric-facing FC Ports
The Aggregator, with the FC ports, are congured by default to operate in N port mode to connect to an F port on an FC switch in a
fabric. You can apply only one FCoE map on an FC port.
When you apply an FCoE map on a fabric-facing FC port, the FC port becomes part of the FCoE fabric, whose settings in the FCoE
map are congured on the port and exported to downstream server CNA ports.
Each Aggregator, with the FC port, is associated with an Ethernet MAC address (FCF MAC address). When you enable a fabric-
facing FC port, the FCoE map applied to the port starts sending FIP multicast advertisements using the parameters in the FCoE
map over server-facing Ethernet ports. A server sees the FC port, with its applied FCoE map, as an FCF port.
Step Task Command Command Mode
1
Congure a fabric-facing FC port.
interface fibrechannel
slot/port
CONFIGURATION
2
Apply the FCoE and FC fabric congurations in an FCoE
map to the port. Repeat this step to apply an FCoE map to
more than one FC port, for example:
Dell# interface fi 0/9
Dell(config-if-fc-0/9)# fabric
SAN_FABRIC_A
fabric
map-name
INTERFACE
FIBRE_CHANNEL
3
Enable the port for FC transmission.
no shutdown
INTERFACE
FIBRE_CHANNEL
Important Points to Remember
You can apply a DCB or FCoE map to a range of Ethernet or Fibre Channel interfaces by using the interface range command;
for example:
Dell(config)# interface range tengigabitEthernet 1/12 - 23 , tengigabitEthernet 2/24 - 35
Dell(config)# interface range fibrechannel 0/0 - 3 , fibrechannel 0/8 - 11
Enter the keywords interface range followed by an interface type and port range. A port range must contain spaces before
and after the dash. Separate each interface type and port range with a space, comma, and space as shown in the preceding
examples.
Sample Conguration
1. Congure a DCB map with PFC and ETS settings:
Dell(config)# dcb-map SAN_DCB_MAP
Dell(config-dcbx-name)# priority-group 0 bandwidth 60 pfc off
Dell(config-dcbx-name)# priority-group 1 bandwidth 20 pfc on
Dell(config-dcbx-name)# priority-group 2 bandwidth 20 pfc on
Dell(config-dcbx-name)# priority-group 4 strict-priority pfc off
256