Administrator Guide
EXEC mode
Dell# show interfaces port brief
Codes: L - LACP Port-channel
O - OpenFlow Controller Port-channel
LAG Mode Status Uptime Ports
127 L2 up 00:18:22 Fo 0/33 (Up)<<<<<<<<ICL LAG
Fo 0/37 (Up)
L 128 L2 up 00:00:00 Fo 0/41 (Up)<<<<<<<<Uplink LAG
Virtual Link Trunking (VLT) in PMUX Mode
VLT allows the physical links between two devices (known as VLT nodes or peers) within a VLT domain to be considered a single
logical link to connected external devices.
For VLT operations, use the following congurations on both the primary and secondary VLT. Ensure the VLTi links are connected
and administratively up. VLTi connects the VLT peers for VLT data exchange.
1. Congure VLTi.
Dell#configure
Dell(conf)#int port-channel 127
Dell(conf-if-po-127)# channel-member fortygige 0/33,37
Dell(conf-if-po-127)# no shutdown
Dell(conf-if-po-127)# end
2. Congure the VLT domain.
Dell#configure
Dell(conf)#vlt domain 1
Dell(conf-vlt-domain)# peer-link port-channel 127
-> VLT peer destination
Dell(conf-vlt-domain)# back-up destination 169.254.31.23
Dell(conf-vlt-domain)#system-mac mac-address
00:01:09:06:06:06
->
unit-id 0 – VLT Primary, unit-id 1 – VLT Secondary
Dell(conf-vlt-domain)# unit-id 0
Dell(conf-vlt-domain)#end
3. Congure the VLT port channel. In the following example, the local and remote VLT port-channels are the same but you can also
use dierent VLT port-channels.
Dell#configure
Dell(conf)#int port-channel 128
Dell(conf-if-po-128)# portmode hybrid
Dell(conf-if-po-128)# switchport
Dell(conf-if-po-128)# vlt-peer-lag port-channel 128
Dell(conf-if-po-128)# link-bundle-monitor enable
Dell(conf-if-po-128)# no shutdown
Dell(conf-if-po-128)# end
4. Show the VLT peer status.
Dell#show vlt brief
VLT Domain Brief
------------------
Domain ID: 1
Role: Primary
Role Priority: 32768
ICL Link Status: Up
HeartBeat Status: Up
VLT Peer Status: Up
Local Unit Id: 0
Version: 6(2)
Local System MAC address: 00:01:e8:e1:e1:c3
Remote System MAC address: f8:b1:56:0e:b1:7f
PMUX Mode of the IO Aggregator
219