Administrator Guide
---------------------------------------STANDBY
UNIT------------------------------------------
10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Stack Port 50 has flapped 5 times within 10
seonds.Shutting down this stack port now.
10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/module
and power-cycle the stack.
Master Switch Recovers from Failure
• Problem: The master switch recovers from a failure after a reboot and rejoins the stack as the standby unit or member unit.
Protocol and control plane recovery requires time before the switch is fully online.
• Resolution: When the entire stack is reloaded, the recovered master switch becomes the master unit of the stack.
Stack Unit in Card-Problem State Due to Incorrect Dell Networking OS Version
• Problem: A stack unit enters a Card-Problem state because the switch has a dierent Dell Networking OS version than the
master unit. The switch does not come online as a stack unit.
• Resolution: To restore a stack unit with an incorrect Dell Networking OS version as a member unit, disconnect the stacking
cables on the switch and install the correct Dell Networking OS version. Then add the switch to the stack as described in Adding
a Stack Unit. To verify that the problem has been resolved and the stacked switch is back online, use the show system
brief command.
Dell#show system brief
Stack MAC : 00:1e:c9:f1:00:9b
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
--------------------------------------------------------------------------
0 Management online I/O-Aggregator I/O-Aggregator 8-3-17-46 56
1 Standby
card problem I/O-Aggregator unknown 56
2 Member not present
3 Member not present
4 Member not present
5 Member not present
Card Problem — Resolved
Dell#show system brief
Stack MAC : 00:1e:c9:f1:04:82
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
----------------------------------------------------------------------
0 Management online I/O-Aggregator I/O-Aggregator 8-3-17-52 56
1 Standby
online I/O-Aggregator I/O-Aggregator 8-3-17-52 56
2 Member not present
3 Member not present
4 Member not present
5 Member not present
Stack Unit in Card-Problem State Due to Conguration Mismatch
• Problem: A stack unit enters a Card-Problem state because there is a conguration mismatch between the logical provisioning
stored for the stack-unit number on the master switch and the newly added unit with the same number.
• Resolution: From the master switch, reload the stack by entering thereload command in EXEC Privilege mode. When the
stack comes up, the card problem will be resolved.
Upgrading a Switch Stack
To upgrade all switches in a stack with the same Dell Networking OS version, follow these steps.
1. Copy the new Dell Networking OS image to a network server.
2. Download the Dell Networking OS image by accessing an interactive CLI that requests the server IP address and image
lename, and prompts you to upgrade all member stack units.
EXEC Privilege mode
Stacking