Reference Guide

Example
(stack-unit)
Dell#show environment stack-unit
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
---------------------------------------------------------------
------------
* 1 online 66C ok 2
* Management Unit
Dell#
Example
(thermal-
sensor)
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
Sensor7
Sensor8 Sensor9
---------------------------------------------------------------
-----------------
----------------
1 51 51 64 61 61 61
67 61
64 66
Dell#
show inventory
Display the switch type, components (including media), and Dell Networking OS version including
hardware identification numbers and configured protocols.
Syntax
show inventory [media slot]
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of
the stack member you want to display pluggable media
inventory.
Defaults none
Command
Modes
EXEC
Supported
Modes
All Modes
Command
History
Version Description
9.4(0.0) Supported on the FN I/O Aggregator.
Usage
Information
If there are no fiber ports in the unit, just the header under show inventory
media displays. If there are fiber ports but no optics inserted, the output displays
"Media not present or accessible".
Example
Dell#show inventory
System Type : PE-FN-410S-IOA
68