Reference Guide

Te 0/12 Up 10000 Mbit Full --
Dell#
show npiv devices
Displays the FCoE and FC devices currently logged into an FN I/O Aggregator Switch with the FC Flex IO
module NPIV proxy gateway.
Syntax
show npiv devices [brief]
Parameters
brief Displays an overview of current server CNA-fabric
connections over an FN I/O Aggregator with the FC Flex IO
module NPIV proxy gateway.
Command
Modes
EXEC
EXEC Privilege
Supported
Modes
All modes
Command
History
Version Description
9.6.(0.0) Supported on the FN2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.
Usage
Information
Use the show npiv devices command to display information on the server CNA,
server-facing Ethernet and fabric-facing FC ports, and the SAN fabric in each
server-fabric connection over an FN I/O Aggregator with the FC Flex IO module
NPIV proxy gateway.
The following table describes the show npiv devices brief output shown in
the example below.
Field Description
ENode-Intf FN I/O Aggregator with the FC Flex IO module Ethernet
interface (slot/port) to which a server CNA is connected.
ENode-WWPN Worldwide port name (WWPN) of a server CNA port.
FCoE-Vlan VLAN ID of the dedicated VLAN used to transmit FCoE traffic
to and from the fabric.
Fabric-Intf Fabric-facing Fibre Channel port (slot/port) on which FC
traffic is transmitted to the specified fabric.
294